Human phosphatidylcholine (PC) Elisa kit

Human phosphatidylcholine (PC) Elisa kit

Manual of Human Phosphatidylcholine (PC) Elisa Kit
The Human Phosphatidylcholine (PC) Elisa kit is for research use only.
Detection range: 96T 20pg / ml-480pg / ml
Purpose: This kit is used to determine the content of phosphatidylcholine (PC) in human serum, plasma and related liquid samples.
Experimental principle: This kit uses the double antibody sandwich method to determine the level of human phosphatidylcholine (PC) in the specimen. The microplate was coated with purified human phosphatidylcholine (PC) antibody to make a solid-phase antibody. Phosphatidylcholine (PC) was added to the monoclonal antibody-coated microwells in turn, followed by HRP-labeled phosphatidylcholine Alkaline (PC) antibody binds to form an antibody-antigen-enzyme-labeled antibody complex. After thorough washing, the substrate TMB is added for color development. TMB is converted into blue under the catalysis of HRP enzyme, and into the final yellow under the action of acid. The color depth is positively correlated with phosphatidylcholine (PC) in the sample. The absorbance (OD value) was measured with a microplate reader at a wavelength of 450 nm, and the concentration of human phosphatidylcholine (PC) in the sample was calculated by a standard curve.
Human phosphatidylcholine (PC) Elisa kit composition:
1 30 times concentrated washing solution 20ml × 1 bottle 7 stop solution 6ml × 1 bottle
2 Enzyme label reagent 6ml × 1 bottle 8 standard (960pg / ml) 0.5ml × 1 bottle
3 Enzyme label coated plate 12 wells × 8 strips 9 standard dilutions 1.5ml × 1 bottle
4 Sample diluent 6ml × 1 bottle 10 instructions 1 copy
5 Developer A solution 6ml × 1 bottle 11 2 sealing film
6 Developer B liquid 6ml × 1 / bottle 12 1 sealed bag
Specimen requirements:
1. Samples containing NaN3 cannot be detected because NaN3 inhibits horseradish peroxidase (HRP) activity.
2. The specimens should be extracted as soon as possible after collection. The extraction should be carried out according to relevant literature. If the test cannot be performed immediately, the specimen can be stored at -20 ℃, but repeated freezing and thawing should be avoided
Steps:
1. Dilution of standard products: This kit provides one original standard product. The user can perform dilution in a small test tube according to the following chart.
480pg / ml No. 5 standard 150μl original standard added 150μl standard dilution
240pg / ml No. 4 standard 150μl No. 5 standard added 150μl standard dilution
120pg / ml No. 3 standard 150μl No. 4 standard added 150μl standard dilution
60pg / ml No. 2 standard 150μl No. 3 standard added 150μl standard dilution
30pg / ml No. 1 standard 150μl No. 2 standard added 150μl standard dilution
2. Add samples: set up blank wells (the blank control wells do not add samples and enzyme reagents, the rest of the steps are the same), standard wells, sample wells to be tested. Accurately add 50μl of standard on the enzyme-coated plate, add 40μl of sample diluent to the sample well, and then add 10μl of sample to be tested (the final dilution of the sample is 5 times) Add the sample and add the sample to the bottom of the well of the microplate, try not to touch the wall of the well, shake gently to mix.
3. Incubation: seal the plate with the sealing film and incubate at 37 ° C for 30 minutes.
4. Mixing solution: Dilute 30 times concentrated washing liquid with distilled water 30 times and reserve
5. Washing: Carefully peel off the sealing film, discard the liquid, spin dry, fill each well with the washing liquid, let it stand for 30 seconds, then discard, repeat 5 times and pat dry.
6. Add enzyme: add 50μl of enzyme label reagent to each well, except blank well.
7. Incubation: The operation is the same as 3.
8. Washing: The operation is the same as 5.
9. Color development: Add 50μl of developer A to each well, and then add 50μl of developer B, mix gently, and develop for 15 minutes in the dark at 37 ℃.
10. Termination: Add 50μl of stop solution to each well to terminate the reaction (at this time, the blue color turns to yellow).
11. Determination: Measure the absorbance (OD value) of each well in sequence with the blank air conditioner at zero and 450nm wavelength. The measurement should be carried out within 15 minutes after adding the stop solution.
Calculation: Taking the concentration of the standard as the abscissa and the OD value as the ordinate, draw a standard curve on the graph paper, and find the corresponding concentration from the standard curve according to the OD value of the sample; then multiply by the dilution factor; The linear regression equation of the standard curve is calculated by the concentration and OD value of the sample, and the OD value of the sample is substituted into the equation to calculate the sample concentration, and then multiplied by the dilution factor, which is the actual concentration of the sample.
Precautions:
1. The kit should be taken out of the refrigerated environment and equilibrated at room temperature for 15-30 minutes before use. If the enzyme-coated plate is unsealed after opening, the strip should be stored in a sealed bag.
2. Crystals may be precipitated in the concentrated washing liquid, which can be heated and dissolved in a water bath during dilution, and the results will not be affected during washing.
3. The sampler should be used at each step of sample addition, and the accuracy should be regularly checked to avoid test errors. It is best to control the sampling time within 5 minutes. If there are many specimens, it is recommended to use a volley gun to add samples.
4. Please make a standard curve at the same time of each measurement, it is best to make a double hole. If the content of the test substance in the specimen is too high (the OD value of the sample is greater than the OD value of the first well of the standard well), please dilute it with a certain multiple of the sample diluent (n times) before measuring, and finally multiply by the total dilution Multiple (× n × 5).
5. The sealing film is limited to one-time use to avoid cross-contamination.
6. Please keep the substrate away from light.
7. Strictly follow the instructions, and the test results must be determined by the microplate reader.
8. All samples, washing liquids and various wastes should be treated as infectious agents.
9. The components of different batches of this reagent shall not be mixed.
10. If there is any difference with the English manual, the English manual shall prevail.
11. Kit storage: 2-8 ° C.
12. Validity: 6 months

25cc Chainsaw

Chainsaw: Gasoline chainsaw. This is the smallest kind of chainsaw. It is powered by a small two-stroke gasoline engine, similar to the Brush Cutter, Outboard Motor, driven by a sprocket, and runs on the guide board through a dedicated cutting saw chain to achieve the purpose of cutting and pruning wood, branches, ice and other themes. Mainly used for landscaping pruning, replacing the special guide board can be used as a large wood carving, ice carving large outline modification

Chainsaw products have many advantages, such as large power, small vibration, high cutting efficiency and low cutting cost. It has become the leading hand-held logging machine in the forest area.

The chainsaw shock absorption system uses springs and high strength rubber shock absorption. Sprocket form for positive teeth, make the assembly chain more simple and convenient!

Excellent and reliable ignition device, oil supply system using adjustable oil pump.

Before use, you must read the operation manual carefully to understand the characteristics, technical performance and precautions of the chainsaw.

Before use, the fuel tank, the fuel tank of the machine to add enough oil; Adjust the tightness of the saw chain, neither too loose nor too tight.

Before operation, the operator should wear work clothes, helmet, protective gloves, dust-proof glasses or facial protective cover.

After the engine starts, the operator holds the rear saw handle with his right hand and the front saw handle with his left hand. The Angle between the machine and the ground should not exceed 60 degrees, but the Angle should not be too small, otherwise it is not easy to operate.

When cutting, cut off the lower branches first, and then saw the upper branches. Heavy or large branches should be cut in sections.

25cc petrol chainsaw,chainsaw parts,cordless chain saw,pole chain saw,gasoline chain saw

Shaoxing Haotuo Machinery CO., LTD. , https://www.haotuochinatools.com